外文翻译---电力机车交-直分相装置上产生电弧的仿真实验
《外文翻译---电力机车交-直分相装置上产生电弧的仿真实验》由会员分享,可在线阅读,更多相关《外文翻译---电力机车交-直分相装置上产生电弧的仿真实验(13页珍藏版)》请在毕设资料网上搜索。
1、附录 A(原文 ) A Simulation of Arc Generation at AC-DC Neutral Section of Electric Railway Youngsoo Han, Kyuhyoung Choi Abstract-This paper provides an experimental and theoretical analysis of the arc discharges generated between contact wire and pantograph of high speed railway. A video-based arc detect
2、ion device is installed on the KTX train, and arc discharges are measured for a 45.87km track section of high speed railway in Korea. It is measured that the rate of contact loss is 0.3% which is lower than the regulated value of 1.0% for high speed train, and arc discharges induced by 21 small size
3、 contact losses and 6 medium size contact losses occur continuously along the track. The power of arc discharge between contact wire and pantograph is calculated as 9.022.5kW which is approximately one-hundredth of that of the arc discharges generated at the neutral section of contact wire. The resu
4、lts of the measurement and the analysis suppose that a study be followed to suppress arc discharges and contact wire damages for the safe operation of high speed railway. Index Terms Electric railway;arc discharge;contact loss;contact wire; pantograph;neutral section. I.NOMENCLATURE S/S : Sub-Statio
5、n of Electric Railway SP : Sectioning Post SSP : Sub- Sectioning Post AT : Auto-Transformer TF : Trolley Feeder AF : Auto- Transformer Feeder FPW : Fault Protective Wire NW : Neutral Wire NS : Neutral Section CCTV: Closed Circuit Television EMI: Electromagnetic Interference LAN: Local Area Network M
6、CB: Main Circuit Breaker KTX: Korea Train Express II.INTRODUCTION Catenary systems play a important role in supplying electric power without interruption to trains moving fast. The pantographs installed on train collect currents for traction while keeping in contact with the catenary system. Arc dis
7、charges occur between the contact wire and the pantographs, when the pantographs happen to lose contact with the contact wire.Arc discharge also occurs when the train passes through the AC-DC neutral section of the catenary system where electricity is not supplied. These arc discharges give rise to
8、many problems such as spoiling the contact wire and the pantographs,and inducing EMI phenomena,audible noises and other environmental pollutions.Arc discharges generally have large heating power which may spoil the slider of pantograph made of sintered alloy and even breaks the contact wires.Voltage
9、 surges induced by arc discharges may produce EMI problems to the small size environment or mal-operation of electronic devices on the train. The damages caused by arc discharge will be more critical for high speed railway.The faster train moves,the more difficult to keeping in contact with catenary
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中设计图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 外文 翻译 电力机车 直分相 装置 产生 发生 电弧 仿真 实验 试验