1、英文原文 Electrical Winch Controls by Tom Young The form of motor control we all know best is the simple manual station with up and down pushbuttons. While these stations may still be the perfect choice for certain applications, a dizzying array of more sophisticated controls is also available. This art
2、icle addresses the basic electrical requirements of the motors and user interface issues you will need to address before spcifying, building or buying winch controls. begin with, the manual control stations should be of the hold-to-run type, so that if you take your finger off of the button the winc
3、h stops. Additionally, every control station needs an emergency stop (E-stop) that kills all power to the winch, not just the control circuit. Think about it if the winch isnt stopping when it should, you really need a failsafe way to kill the line power. Its also a great idea to have a key operated
4、 switch on control stations, especially where access to the stations is not controlled. Safe operation by authorized personnel must be considered when designing even the simplest manual controls. Controlling Fixed Speed Motors The actual controlling device for a fixed speed winch is a three phase re
5、versing starter. The motor is reversed by simply switching the phase sequence from ABC to CBA. This is accomplished by two three-pole contactors, interlocked, so they cant both be closed at the same time. The NEC requires both overload and short circuit protection. To protect the motor from overheat
6、ing due to mechanical overloads a thermal overload relay is built into the starter. This has bi-metallic strips that match the heating pattern of the motor and trips contacts when they overheat. Alternatively,a thermistor can be mounted in the motor winding to monitor the motor temperature. Short ci
7、rcuit protection is generally provided by fuses rated for use with motors. A separate line contactor should be provided ahead of the reversing contactor for redundancy. This contactor is controlled by the safety circuits: E-stop and overtravel limits. This brings us to limit switches. When you get t
8、o the normal end of travel limit the winch stops and you can only move it in the opposite direction (away from the limit). There also needs to be an overtravel limit in case, due to an electrical or mechanical problem, the winch runs past the normal limit. If you hit an overtravel limit the line con
9、tactor opens so there is no way to drive off of the limits. If this occurs, a competent technician needs to fix the problem that resulted in hitting the overtravel limit. Then, you can override the overtravels using the spring return toggle switch inside the starter as opposed to using jumpers or ha
10、nd shooting the contactors. Variable Speed Requirements Of course, the simple fixed speed starter gets replaced with a variable speed drive. Heres where things start to get interesting! At the very least you need to add a speed pot to the control station. A joystick is a better operator interface, a
11、s it gives you a more intuitive control of the moving piece. Unfortunately, you cant just order any old variable speed drive from your local supplier and expect it to raise and lower equipment safely and reliably over kids on stage. Most variable speed drives wont, as they arent designed for lifting