外文翻译--风扇轴失效原因的调查
《外文翻译--风扇轴失效原因的调查》由会员分享,可在线阅读,更多相关《外文翻译--风扇轴失效原因的调查(26页珍藏版)》请在毕设资料网上搜索。
1、PDF外文:http:/ 5400 字 出处: Engineering Failure Analysis, 2010, 17(5): 1188-1194 附录 A Investigation of causes of fan shaft failure M. Ristivojevic, R. Mitrovic and T. Lazovic Belgrade University, Faculty of Mechanical Engineering, Kraljice Marije 16, Belgrade 11120, Serbia Abstract Ene
2、rgy efficiency of thermal power plants depends on the vital plant elements reliability levels. In order to preserve high level of energy efficiency, the vital elements operational capability is continually monitored via observing the working temperature, vibration and noise levels. Yet, however, in
3、spite of this, and usually due to inadequate maintenance, inadequate assembly, errors in the design or manufacturing processes, or due to accidents, abrupt failures of the plants vital elements can occur. An example for this is the volumetric destruction of the fresh air fan shaft due to melting of
4、the shaft at the shafts stationary support. In addition to shaft destruction, the fan bearing and wheel blades have undergone destruction as well. This breakdown has occurred in the course of continual monitoring of the bearing service temperature and vibrations levels. Former studies, aimed at dete
5、rmining the breakdown causes, were based on the detailed examination of the damaged elements materials and detailed analysis of the bearing setting arrangement. Considering the fact that the shaft stationary support was realized by means of a double-pressed joint, a thorough analysis has been made i
6、n this paper of the pressed joint operational capability in the boundary service conditions, in order to determine the extent to which the pressed joint participated in the breakdown. Keywords: Fan; Shaft; Ball bearing; Pressed joint; Temperature Article Outline 1. Introduction 2. Setting arrangemen
7、t analysis in fixed shaft support 3. Bearing setting arrangement breakdown condition description 4. Double-pressed joint analysis vs. bearing setting operational capability 5. Conclusion References 1. Introduction Fresh air fan feeds fresh air into the thermal power plant boiler. The fan uses a high
8、-voltage AC electric motor as the driving machine, to which it is connected by way of a flexible coupling. The fan consists of a pre-wheel, 13-blade working wheel and a shaft. Fan shaft is embedded on two double-row, self-adjusting barrel-shaped bearings of the 22340 CC/W33 type, with steel cages, f