生物医学工程外文翻译
《生物医学工程外文翻译》由会员分享,可在线阅读,更多相关《生物医学工程外文翻译(12页珍藏版)》请在毕设资料网上搜索。
1、咸宁学院本科毕业设计(论文):全自动生化分析仪的维护与保养 0 毕业论文(设计) 外文翻译 译文题目 :生化的分析者 将 Olli C + D 使用在朝派酶学一年后的评价 学生姓名: 吕锦阳 学 号: 050921060 专 业: 生物医学工程 方 向: 医疗器械 指导教师: 但汉久 2008 年 12 月 29 日 咸宁学院本科毕业设计(论文):全自动生化分析仪的维护与保养 1 Evaluation of the Olli C + D biochemical analyser after over a year of use in enzymology G. Baraton, D. Graf
2、meyer, A. Capuano, L. Richard and J. Sofia. Laboratoire automatisde Biochimie Clinique, (Professeur J. Bertrand), HopitalEdouardHerriot, Place dArsonval, 69374 Lyon Cedex 2, France To meet todays clinical requirements, clinical biochemistry laboratories must be increasingly automated. The required c
3、riteria for an automatic analyser are reliability; the ability to change chemical reactions easily and quickly; rapid determinations and low analysis cost. It appears that the Olli C + D parallel analyser (Kone Oy instrument division Espoo, Finland) answers these criteria. A report on the Olli C sys
4、tem has already been published by Puuka and Pukka 1. This evaluation, using the C + Dsystem, deals with its intensive and daily use in enzymology over a period lasting more than one year. Description The instrument is a parallel, multichannel, photometric analyser. The different phases of determinat
5、ion are performed in batches of 24 samples including blanks, standards and controls. The rate of analysis is 700 tests per hour with end point determinations of 360 kinetic measurements per hour reaction time is 21A minutes. The analyser comprises three independent units, the sample diluter/processo
6、r, photometer (each controlled by microprocessor) and incubator. The sample change is performed by hand using disposable cuvettes in a thermostatedblock. The Olli D Diluter measures 350 x 1100 x 740 mm and weighs 70 kg. It is made up of a dispensing tray with 24 cuvette blocks which fit in the Olli
7、C photometer, eight reagent vessels, one block with 24 serum vials, an eight tip dispensing head and a digital display and keyboard. The diluter can be programmed by hand or by tape cassette for 30 analyses; it is possible to add serum and up to eight reagents distributed in one or several runs. Eac
8、h analysis programme follows the sequence:l. Attain reaction temperature (25, 30, 37C). 2. Measure reagent (5 to 1000/al by steps of 1/.tl) and position. 3. Measure and add sample. 4. Mix(5 to 180 seconds). The photometer measures 330 x 520 x 740 mm and weighs 48 kg. It comprises a computer, a therm
9、al pri_nter and a thermostated measuring chamber (25, 30, 37C). The light source is a zenon lamp. A quartz optic fibre system allows the simultaneous measurement of 24 cuvettes. Filters have a bandwidth of 8 to 15 nm. The smallest readable volume is 500 /al for end point determinations, and 300/1 fo
10、r kinetic determinations. The photometer can be programmed by hand or by tape cassette for 15 analyses which may be made in end point mode, with or without blank measurement, or in kinetic mode, with or without reagent or serum blanks. Kinetics determinations are made using linear regression of 12 t
11、o 24 measurements in to 10 minutes. The results are printed with the name and units of the programmed analysis. Error messages are printed; eg, if the chosen initial absorbance limits have been exceeded or if there is non-linearity of reaction. In addition, it is possible to have printed the twelve