机械类外文翻译--声发射检测初生空化及其应用60KW离心泵最佳效率点案例研究
《机械类外文翻译--声发射检测初生空化及其应用60KW离心泵最佳效率点案例研究》由会员分享,可在线阅读,更多相关《机械类外文翻译--声发射检测初生空化及其应用60KW离心泵最佳效率点案例研究(13页珍藏版)》请在毕设资料网上搜索。
1、PDF外文: http:/ 45 页 共 57 页 中文 2940 字 出处: NDT & E International, 2005, 38(5): 354-358 The application of Acoustic Emission for detecting incipient cavitation and the best efficiency point of a 60KW centrifugal pump; case study  
2、; L. Alfayez, D. Mba, G. Dyson July 2005AbstractPumps play a significant role in Industrial plants and need continuous monitoring to minimize loss of production. To date, there is limited published information on the application of Acoustic Emission (AE)to incipient pump cavitat
3、ion. This paper presents a case study where AE has been applied for detecting incipient cavitation and determining the best efficiency point (BEP)of a 60KW centrifugal pump. Results presented are based on NPSH (Net Positive Suction Head)and performance tests. In conclusion the AE technique was shown
4、 to offer early detection of incipient cavitation, furthermore, the technique has demonstrated the ability to determine the BEP of a pump Keywords: Acoustic Emission; best efficiency point; cavitation; condition monitoring; Pump performance 1. Introduction Typically the pump manufacturer will
5、undertake performance and NPSH(Net Positive Suction Head)tests on supplied pumps, the significance of the latter is to determine the 3%drop in head at which serious cavitations will occur. The NPSH can be expressed as the difference between the suction head and the liquids vapour head. The concept o
6、f NPSH was developed for the purpose of comparing inlet condition of the system with the inlet requirement of the pump. Cavitation causes a loss of pump efficiency and degradation of the mechanical integrity of the pump. It must be noted that cavitation starts to develop before the 3%drop in head. I
7、t is generally accepted that the critical pressure for inception of cavitation is not constant and varies with operation fluid physical properties and the surface roughness xx 大学机械工程学院毕业设计(论文) 第 46 页 共 57 页 of the hydraulic equipment. Application of the high freq
8、uency Acoustic Emission (AE)technique in condition monitoring of rotating machinery has been growing over recent years1-9.Typical frequencies associated with AE activity range from 20 KHz to 1MHz.The most commonly used method for identifying the presence of cavitation is based on observations of the
9、 drop in head. Whilst other techniques such as vibration analysis and hydrophone observations for pump fault diagnosis are well established, the application of AE to this field is still in its infancy. In addition, there are a limited number of publications on the application of AE to pump health an
10、d cavitation monitoring. Derakhshan et al 10investigated the cavitation bubble collapse as a source of acoustic emission and commented that the high amplitude pressure pulse associated with bubble collapse generated AE. With the AE sensor was placed on the actual specimen experiencing cavitation &nb
11、sp;Derkhshan observed increasing AE r.m.s levels with increased pressure of flow and cavitation. However, with the AE sensor mounted on the tank wall the reverse was observed, decreasing AE r.m.s levels with increasing pressure and cavitation. This was attributed to a visible bubble cloud that incre