基于PLC双电源开关设计外文翻译
《基于PLC双电源开关设计外文翻译》由会员分享,可在线阅读,更多相关《基于PLC双电源开关设计外文翻译(7页珍藏版)》请在毕设资料网上搜索。
1、 毕业设计( 外文翻译 ) 英文 题目 Based on PLC dual power switch design 中文题目 基于 PLC 双电源开关设计 系 (院) 自动化系 专 业 电气自动化技术 学生姓名 曹成帅 李广斌 孙凤宝 学 号 20009022384, 2009022410, 2009022427,2009022390 指导教师 张宝国 职 称 副教授 年 月 日 滨州学院专科毕业设计 (外文翻译 ) 2 Intelligent double power 1 Intelligent dual power supply switching technology In this p
2、aper, the double load - dual power automatic switching of PLC control, PLC control program to replace relay logic control circuits, it has the three-phase power supply phase detection and protection switching function, power returned to normal after the automatic reverse switch, when a fault and res
3、tore normal respectively sends out two difference clear alarm and prompt sound. Double load - dual power automatic switching control of PLC, the open-phase protection mainly adopts the technical proposal that : setting the three-phase open-phase detection signal circuit, the three-phase open-phase d
4、etection signal circuit directly from the main circuit of three-phase power supply, namely the intermediate relay KA1-KA3 and KA4-KA6, respectively connected to power supply main loop U1 and U2 A, B and C single phase circuit, KA1-KA3 and KA4-KA6 normally open contacts respectively as PLC input sign
5、al, namely as the preparation of PLC U1 and U2 three-phase open-phase detection logic control program input conditions. With short phase protection double load - dual power automatic switching control, not only has the open-phase protection, but also has a short circuit and overload protection, unde
6、r-voltage protection function; automatic phase lack detection, three-phase current display, a road power supply circuit can automatically switch to another power source to load power supply, light and sound alarm; in the power supply return to normal after automatic reverse switch; in the event of a
7、 failure and return to normal when respectively sends out two difference obvious alarm and prompt sound effects. It overcomes the shortcomings of low double power supply switching control system without phase protection, can automatically reverse switch, as well as fault and return to normal when us
8、ing a single audio prompts defects. The control system has perfect function, reliable performance, simple circuit structure, low manufacturing cost etc. 2 Intelligent dual power supplies switching main circuit control With short phase protection double load - dual power automatic switching control c
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中设计图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 基于 plc 双电源 开关 设计 外文 翻译