1、PDF外文:http:/ 2500 字 附录一:英文技术资料翻译 英文原文: Emerg Infect Dis. 2008 August; 14(8): 12551258. doi: 10.3201/eid1408.080059 PMCID: PMC2600390 Cutaneous Infrared Thermometry for Detecting Febrile Patients Pierre Hausfater, Yan Zhao,Stphanie Defrenne, Pascale Bonnet, and Bruno Riou* Aut
2、hor informationCopyright and License information This article has been cited by other articles in PMC. Abstract We assessed the accuracy of cutaneous infrared thermometry, which measures temperature on the forehead, for detecting patients with fever in patients admitted to an emergency departm
3、ent. Although negative predictive value was excellent (0.99), positive predictive value was low (0.10). Therefore, we question mass detection of febrile patients by using this method. Keywords: Fever, mass detection, cutaneous infrared thermometry, infectious diseases, emergency, dispatch Recent eff
4、orts to control spread of epidemic infectious diseases have prompted health officials to develop rapid screening processes to detect febrile patients. Such screening may take place at hospital entry, mainly in the emergency department, or at airports to detect travelers with increased body temperatu
5、res (13). Infrared thermal imaging devices have been proposed as a noncontact and noninvasive method for detecting fever (46). However, few studies have assessed their capacity for accurate detection of febrile patients in clinical settings. Therefore, we undertook a prospective study in an emergenc
6、y department to assess diagnostic accuracy of infrared thermal imaging. The Study The study was performed in an emergency department of a large academic hospital (1,800 beds) and was reviewed and approved by our institutional review board (Comit de Protection des Personnes se Prtant la Recherche Bio
7、mdicale Piti-Salptrire, Paris, France). Patients admitted to the emergency department were assessed by a trained triage nurse, and several variables were routinely measured, including tympanic temperature by using an infrared tympanic thermometer (Pro 4000; Welch Allyn, Skaneateles Falls, NY, USA),
8、systolic and diastolic arterial blood pressure, and heart rate. Tympanic temperature was measured twice (once in the left ear and once in the right ear). This temperature was used as a reference because it is routinely used in our emergency department and is an appropriate estimate of central core t
9、emperature (79). Cutaneous temperature was measured on the forehead by using an infrared thermometer (Raynger MX; Raytek, Berlin, Germany) (Figure 1). Rationale for an infrared thermometer device instead of a larger thermal scanner was that we wanted to test a method (i.e., measurement of forehead c
10、utaneous temperature by using a simple infrared thermometer) and not a specific device. The forehead region was chosen because it is more reliable than the region behind the eyes (5,10). The latter region may not be appropriate for mass screening because one cannot accurately measure temperature thr
11、ough eyeglasses, which are worn by many persons. Outdoor and indoor temperatures were also recorded. Figure 1 Measurement of cutaneous temperature with an infrared thermometer. A) The device is placed 20 cm from the forehead. B) As soon as the examiner pulls the trigger, the temperature measur