1、To ensure stable operation of electrostatic precipitator efficiency measures ESP is a highly efficient dust collector, has been more and more used by coal-fired power plants. Electrostatic precipitator in order to maintain long-term, high-performance and stable operation, it should be affecting the
2、efficiency of electrostatic precipitator factors analysis, and to the strengthening of electrostatic precipitator operation, maintenance and overhaul management. 1 Affect the efficiency of electrostatic precipitator dust factor 1.1 High-low-voltage power supply control device design and operation of
3、 the poor Reasonable corona ESP power is to ensure safe, stable operation of one of the important factors. ESP 380V DC high voltage from high-voltage alternating current flowing through thyristor rectifier equipment supply, electric dust collector of high-voltage power supply impedance is a load cha
4、nge. Impedance when the electric field increased ER-hour requirements of equipment to automatically step-up; lower impedance when the electric field and current become larger, the requirements of equipment to automatically step-down in order to maintain the current settings. Internal transformer rec
5、tifier voltage and current sampling resistor, the introduction of negative feedback signals, processed by the microcomputer intelligent control thyristor phase-shift of the conduction angle, the output voltage to change the load to the purpose of output, so that the most effective electric field of
6、corona power. However, some power and control equipment, factory production control of the controller of the device characteristics and control methods are not perfect protection, etc., coupled with the power plant operation and maintenance personnel of equipment There is a certain understanding of
7、the principles of the blind spot, resulting in power supply poor operation of control devices. 1.2 vibration cleaning device operating mode unreasonable At present, thermal power plants in addition to the use of electricity, and all is vibration cleaning methods. In the vibration intensity and unifo
8、rmity requirements are met, the vibration system (cycle time, the way) is reasonable for the efficiency of electrostatic precipitator dust impact. Vibration cycle, the impact on the collection efficiency is to be able to make when cleaning off the dust from falling into the ash bucket directly block
9、. Vibration cycle is too long, fouling plate thickness, will reduce the dust in the very board charged the conductive properties, reducing collection efficiency; vibration cycle is too short, dust will be dispersed into falling, have given rise to the second dust , that is deposited on the electrost
10、atic precipitator dust collecting on the pole again with a dust collector currents, in particular the electric field at the end of the second polar dust would greatly reduce the efficiency of electrostatic precipitator. Dust caused by the second there are many factors, such as high resistivity dust,
11、 resulting in anti-corona electric field collecting the uneven distribution of the flue gas flow rate or flow rate caused by high turbulence and swirl. Therefore, the requirements of the electric field of flue gas flow rate of not more than 3m / s, the general operation of the electric field in the
12、flue gas flow rate 1.5m / s or so, and the possible distribution of flue gas flow, and the vibration frequency of cleaning off is caused by dust Secondary dust factor. Follow certain procedures, using appropriate test methods, establish the right vibration system, at the same time strengthen the gra