1、 (一) What is Maximum Power Point Tracking (MPPT) and How Does it Work? Photovoltaic (PV) generation is becoming increasingly important as a renewable source since it offers many advantages such as incurring no fuel costs, not being polluting, requiring little maintenance, and emitting no noise, amon
2、g others. PV modules still have relatively low conversion efficiency; therefore, controlling maximum power point tracking (MPPT) for the solar array is essential in a PV system. The amount of power generated by a PV depends on the operating voltage of the array. A PVs maximum power point (MPP) varie
3、s with solar insulation and temperature. Its V-I and V-P characteristic curves specify a unique operating point at which maximum possible power is delivered. At the MPP, the PV operates at its highest efficiency. Therefore, many methods have been developed to determine MPPT. Maximum Power Point Trac
4、king, frequently referred to as MPPT, is an electronic system that operates the Photovoltaic (PV) modules in a manner that allows the modules to produce all the power they are capable of. MPPT is not a mechanical tracking system that “physically moves” the modules to make them point more directly at
5、 the sun. MPPT is a fully electronic system that varies the electrical operating point of the modules so that the modules are able to deliver maximum available power. Additional power harvested from the modules is then made available as increased battery charge current. MPPT can be used in conjuncti
6、on with a mechanical tracking system, but the two systems are completely different. To understand how MPPT works, lets first consider the operation of a conventional (non-MPPT) charge controller. When a conventional controller is charging a discharged battery, it simply connects the modules directly
7、 to the battery. This forces the modules to operate at battery voltage, typically not the ideal operating voltage at which the modules are able to produce their maximum available power. The PV Module Power/Voltage/Current graph shows the traditional Current/Voltage curve for a typical 75W module at
8、standard test conditions of 25C cell temperature and 1000W/m2 of isolation. This graph also shows PV module power delivered vs module voltage. For the example shown, the conventional controller simply connects the module to the battery and therefore forces the module to operate at 12V. By forcing th
9、e 75W module to operate at 12V the conventional controller artificially limits power production to53W. Rather than simply connecting the module to the battery, the patented MPPT system in a Solar Boost charge controller calculates the voltage at which the module is able to produce maximum power. In
10、this example the maximum power voltage of the module (VMP) is 17V. The MPPT system then operates the modules at 17V to extract the full 75W, regardless of present battery voltage. A high efficiency DC-to-DC power converter converts the 17V module voltage at the controller input to battery voltage at
11、 the output. If the whole system wiring and all was 100% efficient, battery charge current in this example would be VMODULE VBATTERY x IMODULE, or 17V 12V x 4.45A = 6.30A. A charge current increase of 1.85A or 42% would be achieved by harvesting module power that would have been left behind by a con
12、ventional controller and turning it into useable charge current. But, nothing is 100% efficient and actual charge current increase will be somewhat lower as some power is lost in wiring, fuses, circuit breakers, and in the Solar Boost charge controller. Actual charge current increase varies with ope
13、rating conditions. As shown above, the greater the difference between PV module maximum power voltage VMP and battery voltage, the greater the charge current increase will be. Cooler PV module cell temperatures tend to produce higher VMP and therefore greater charge current increase. This is because
14、 VMP and available power increase as module cell temperature decreases as shown in the PV Module Temperature Performance graph. Modules with a 25C VMP rating higher than 17V will also tend to produce more charge current increase because the difference between actual VMP and battery voltage will be g
15、reater. A highly discharged battery will also increase charge current since battery voltage is lower, and output to the battery during MPPT could be thought of as being “constant power”. What most people see in cool comfortable temperatures with typical battery conditions is a charge current increas