1、外文翻译( 原 文) Power System Monitoring and Control Facilities on Protective Relays Abstract: It is now possible to consider integrating the functions of the power system protection systems with those of the local and remote data collection and control systems. A structured approach to this integration i
2、s necessary. However, if the full benefits are to be realized. A solution which will solve many of the problems previously associated with this integration is presented together with an example of how it might in future be applied in a typical substation. Keywords: Digital communications, Integratio
3、n 1. Introduction The current practice in power system transmission and distribution environments is to separate the functions of the local control, protection and supervisory control and data acquisition (SCADA) systems. One reason for this has been the technical constraint that has limited the amo
4、unt of integration which can be reliably achieved. Local control facilities have consisted of hardwired panels taking up much control room space. Control logic has been provided by hardwired contacts or programmable logic controllers. Until recently much of the protection equipment has consisted of
5、analogue devices, again taking up much space. Most modern protection devices using electronic and microprocessor technologies have so far concentrated on reducing the space taken to implement traditional protection functions. Generally, SCADA systems have been added more recently and have supplied t
6、heir own transducers, interface units and wiring. These have grown up in parallel with the local control and protection systems despite the fact that this often resulted in much functional duplication. Where information concerning the protection operation has been required by the SCADA system this h
7、as been derived in a secondary fashion, for example, feeding the protection outputs back into SCADA digital input units. Recent technology advances have led to the realization that this degree of duplication is becoming less and less necessary. Given infinite computing power it could be argued that
8、the information necessary to perform protection functions is all available or can be made available on the SCADA network. It is conceivable then 外文翻译( 原 文) that the SCADA system could perform its own protection algorithms and issue its own trip signals through its control network. In practice reliab
9、ility requirements and the need for rapid fault clearances have limited this approach to a few specialized instances such as long time thermal overload protection. A far more viable approach is to make the information and control facilities within the relay available to the SCADA network. If this is
10、 done many of the costs associated with the SCADA analogue and digital I/O systems can be reduced. Additionally, if control facilities provided within the protection equipment are utilized, a central substation computer can also be used to replace much of the local control system. One reason for the
11、 failure of systems to integrate protection functions within an overall control package is the sheer amount of processing required. Modern digital protection relays use state of the art microprocessors to provide complex protection functions. When many of these are spread around a substation it is c