1、毕业设计(论文) - 1 - 附录 A:英文参考文献及其翻译 Direct torque control Direct torque control (DTC) is one method used in variable frequency drives to control the torque (and thus finally the speed) of three-phaseAC electric motors. This involves calculating an estimate of the motors magnetic flux and torque based on
2、the measured voltage and current of the motor. Method Statorflux linkage is estimated by integrating the stator voltages. Torque is estimated as a cross product of estimated stator flux linkagevector and measured motor currentvector. The estimated flux magnitude and torque are then compared with the
3、ir reference values. If either the estimated flux or torque deviates from the reference more than allowed tolerance, the transistors of the variable frequency drive are turned off and on in such a way that the flux and torque will return in their tolerance bands as fast as possible. Thus direct torq
4、ue control is one form of the hysteresis or bang-bang control. This control method implies the following properties of the control: Torque and flux can be changed very fast by changing the references High efficiency & low losses - switching losses are minimized because the transistors are switched o
5、nly when it is needed to keep torque and flux within their hysteresis bands The step response has no overshoot No coordinate transforms are needed, all calculations are done in stationary coordinate system No separate modulator is needed, the hysteresis control defines the switch control signals dir
6、ectly There are no PI current controllers. Thus no tuning of the control is required The switching frequency of the transistors is not constant. However, by controlling the width of the tolerance bands the average switching frequency can be kept roughly at its reference value. This also keeps the cu
7、rrent and torque ripple small. Thus the torque and current ripple are of the same magnitude than with vector controlled drives with the same switching frequency. Due to the hysteresis control the switching process is random by nature. Thus there are no peaks in the current spectrum. This further mea
8、ns that the audible noise of the machine is low The intermediate DC circuits voltage variation is automatically taken into account in the algorithm (in voltage integration). Thus no problems exist due to dc voltage ripple (aliasing) or dc voltage transients Synchronization to rotating machine is str
9、aightforward due to the fast control; Just make the torque reference zero and start the inverter. The flux will be identified by the first current pulse 毕业设计(论文) - 2 - Digital control equipment has to be very fast in order to be able to prevent the flux and torque from deviating far from the toleran
10、ce bands. Typically the control algorithm has to be performed with 10 - 30 microseconds or shorter intervals. However, the amount of calculations required is small due to the simplicity of the algorithm The current and voltage measuring devices have to be high quality ones without noise and low-pass