1、附录 A Research on pulse output model digital vortex flow meters The vortex flow meter is widely used in different fields due to its flexibility to various media, non-mobile parts, simple structure and long life etc. However, it has poor performance when operating at low flow rate where the Signal-to-
2、Noise ratio is very small or even the signal is submerged by the noise. The traditional analog vortex flow meter has benefits of steady signal, high accuracy and good real time in the regular flow range, while it also has a disadvantage of weak signal difficult to detect at low flow rate, which lead
3、s to unsatisfying lower limit and a smaller range ratio of 10:1. Based on the previous efforts a pulse output model digital vortex flow meter is developed successfully, which inherits the advantages of the analog one and make up its shortage mentioned above. The digital vortex flow meter with its do
4、uble-core structure that means a couple of CPUs made up of DSP and MSP430 identifies the vortex signals from noises by the frequency spectrum analyzing algorithm in DSP at low flow rate where the analog one is not accurate, or even cant work. Meanwhile it works out by its microcontroller MSP430 the
5、frequency of the vortex signal that is square waves output from pre-amplifier for the vortex signals in the regular flow range where the Signal-to-Noise ratio isnt too much small and the analog one is accurate and real time. This dissertation consists of theory, hardware/software design and experime
6、nt. The main point includes: 1.The scheme called double-channel work model of the pulse output model digital vortex flow meter is designed. The principle is a switch of two different methods to detect the vortex signal. That is using spectrum analysis of digital signal at low flow rate and frequency
7、 counting like analog vortex flow meters in the regular flow range. The critical criterion of the switch point is the uncertainty of the frequency. 2.A pulse output model digital vortex flow meter is developed successfully. The flow meter is studied respectively at DN25 and DN50 pipelines of the wat
8、er flow experiment facility and DN50 and DN100 pipelines of the gas flow experiment facility that locate at Process Detect & Control Laboratory in Tianjin University. And the data shows that the digital flow meter has the property of a better lower limit than the analog one and a bigger range ratio
9、of 1:28.5 41.3. Masses of experiments on the digital vortex flow meter have been carried out at the water flow experiment facility and the gas flow experiment facility of Tianjin University respectively. The result shows that the pulse output model digital vortex flow meter has a satisfying lower li
10、mit that increases the range ratio effectively, strong ability and good real time and thus it is of great practicability. The 21st century is the century information, information and materials and new technology as the main pillar of society from the human revolution is industrialization era to info
11、rmation era, as the perception, acquisition, conversion, processing and transmission of information technology and the indispensable testing instrument, has become an important technology and computer equivalent and daily life and production of all fields. Along with the rapid development of science
12、 and technology, industrial production get continuous development, the detection technology and puts forward many new requirements, and new technology and instrument appearance and further promote the development of science and technology, the development degree of detecting technology has decided t
13、o science and technology level, in other words detection techniques and instruments is the measure of modern science and technology level of a mark. This one, as testing technology is an important part of flow metering with national economic and national defense, science and technology, the close re
14、lationship in economic development plays an important position. After continuous efforts, and technical workers have developed pyretic and various characteristics of flow meter. According to the measuring method and the structure of the classification method, will be divided into differential pressu
15、re meter flowmeter, volumetric flowmeter, fluid flow, ultrasonic vibration flowmeter, mass flowmeter, insert flowmeter open-channel flow and other flowmeter, 11 kinds . The research of the vortex flowmeter belongs to the hydrodynamic vibration flowmeter are widely used . Vortex flowmeter is accordin
16、g to the fluid velocity of vibration frequency and the corresponding principle of work. As early as in 1878 straw Strophe published about fluid velocity relationship with the vibration frequency, straw, vortex frequency is said to stop features of similar size and the velocity of the relationship. P