外文翻译--基于单片机的火灾探测和监控系统
《外文翻译--基于单片机的火灾探测和监控系统》由会员分享,可在线阅读,更多相关《外文翻译--基于单片机的火灾探测和监控系统(9页珍藏版)》请在毕设资料网上搜索。
1、PDF外文:http:/ A:英文附录 Multiple single-chip microcomputer approach to fire detection and monitoring system A.J. AI-Khalili, MSc, PhD D. AI-Khalili, MSc, PhD M.S. Khassem, MSc Indexing term : Hazards, Design, Plant condition monitoring Abstract: A complete system for fire detection and
2、 alarm monitoring has been proposed for complex plants. The system uses multiple single chip architecture attached to a party line. The control algorithm is based on a two-level hierarchy of decision making, thus the complexity is distributed. A complete circuit diagram is given for the local and th
3、e central station with requirements for the software structure. The design is kept in general form such that it can be adapted to a multitude of plant configurations. It is particularly shown how new developments in technology, especially CMOS single chip devices, are incorporated in the system desi
4、gn to reduce the complexity of the overall hardware, e.g. by decomposing the system such that lower levels of hierarchy are able to have some autonomy in decision making, and thus a more complex decision is solved in a simple distributed method. 1 Introduction Regulatory requirements for most high r
5、isk plants and buildings mandate the installation of fire detection and warning systems for all sensitive areas of the plant or the building. Most fire codes state the requirement for monitoring and control specifically related to a type of a plant or building such as chemical plants, petroleum, nuc
6、lear plants, residential high-rises etc. A general conclusion of these codes can be specified as the following requirements : (a) The source of all detector signals should be exactly identifiable by the central station (b) An extra path of communication between the central station and all local cont
7、rollers (c) Direct means of control of alarm and central equipment by the central station (d) Means of communication between the central station and the fire department (e) Availability of emergency power supply. The codes usually also specify the types and frequency of tests for all equipment. A fi
8、re detection and alarm system is a combination of devices designed to signal an alarm in case of a fire. The system may also accomplish fan control, fire door hold or release, elevator recall, emergency lighting control and other emergency functions. These additional functions supplement the basic s
9、ystem which consists of detection and alarm devices and central control unit. Technology has an influence on system architecture. When technology changes, the architecture has to be revised to take advantage of these changes. In recent years, VLSI technology has been advancing at an exponentia
10、l rate. First NMOS and, in the last year or two, CMOS chips have been produced with the same packing density with more gates per chip yet at a lower power consumption than NMOS. Surely this change in technology must affect our design of hardware at both the chip and the system level. At the chip lev
11、el, single chips are now being produced which are equivalent to board levels of only the previous year or two. These chips have microprocessor, memory in RAM and ROM, IO Ports both serial and parallel, A/D timer, flags and other functions on chip. At the system level, the new chips make new architec
12、tures possible. The objective of this paper is to show how technology can influence system architecture in the field of fire control. The new high density single chip microcontrollers are incorporated in the design of a large scale system and yet we obtain a smaller system with a better performance.
13、 In terms of fire detection and alarm monitoring, this is reflected directly in the local station hardware, because of their remoteness and power supply requirements. A complete local station can be designed around a single CMOS chip with power consumption of a few m W depending on system operation.
14、 This approach reduces the cost and complexity of design, implementation and maintenance and provides easily expandable and portable design. This implementation was not possible with old technology. Most of fire detection/monitoring systems availableare tailored towards a specific application and la
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中设计图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 外文 翻译 基于 单片机 火灾 探测 以及 监控 系统
