1、I 摘 要 本设计对 xxxx 图书馆进行了二氧化碳气体灭火系统设计。首先根据二 氧化碳灭火系统设计规范 ,把本图书馆分为了 x 个防护区,采用 x 套灭火剂 贮存装置对其保护,布置了 x个 2和 3号喷头。其次对本图书馆进行了火灾自 动报警系统设计,根据火灾自动报警系统设计规范 ,把本图书馆划分为 x 个报警区域和 x个探测区域,布置了 x个保护半径为 5.8 m和 x个保护半径为 6.7 m 的感烟探测器,并安装了 x 个手自动报警按钮。再次计算并比较了各房 间的安全疏散时间和允许疏散时间,结果表明,火灾时人员能安全逃生。最 后,对本设计进行了经济核算。 关键词:关键词:二氧化碳气体灭火系
2、统;自动报警系统;房间安全疏散 II ABSTRACT This design is to project carbon dioxide gas extinguishing system in Shanghai Normal University Library.First of all, according to the carbon dioxide fire extinguishing systems specifications, this library is divided into 21 protection zones ,uses three sets of fire extin
3、guishing agent storage devices for its protection and layouts 1632 number two and three nozzles . Secondly, I design automatic fire alarm system for this library. Based on the automatic fire alarm system design specifications, the library is divided into six alarm zones and 54 detection area. It als
4、o layouts 31 smoke detector with protection radius of 5.8 m and 23 smoke detector with protection radius of 6.7 m, and installed 25 hand automatic alarm button. After we have re-calculated and compared the safe evacuation time and allow the evacuation time in every room, its result shows that people
5、 can escape to safety in the fire. Finally, we can calculate the cost of this design. Key words: CO2 gas fire extinguishing system; automatic alarm system; the safety evacuation room I 目 录 摘摘 要要 I ABSTRACT . II 1 xxxxxxxx 图书馆概况图书馆概况. 1 1.1基本概况 . 1 1.2 自然气候条件 . 2 2 二氧化碳气体灭火系统设计二氧化碳气体灭火系统设计 3 2.1 防护区的
6、划分 . 3 2.2 二氧化碳用量计算 . 4 2.2.1 二氧化碳设计灭火浓度 4 2.2.2 二氧化碳设计用量计算 5 2.3 二氧化碳储存量和储存容器个数计算 . 9 2.3.1 二氧化碳储存量计算 9 2.3.2 二氧化碳储存容器个数计算 10 2.4 灭火时间的确定 . 10 2.5 管网计算 11 2.5.1 喷头保护半径的选择 .11 2.5.2 管网布置 .11 2.5.3 管网设计流量计算 12 2.6初定管径 . 15 2.7管段计算长度的确定 . 16 2.8 二氧化碳管道压力降计算 . 19 2.9 喷嘴的选择 . 26 2.10 小结 . 30 3 火灾自动报警系统设计火灾自动报警系统设计 32 3.1 报警区及探测区的划分 . 32 II 3.2 火灾探测器的选择 . 35 3.3 火灾探测器数目的确定 . 35 3.4 火灾探测器的安装 . 38 3.5 手动火灾报警按钮的布置 . 41 3.6 小结 . 41 4 房间安全疏散房间安全疏散 43 4.1房间允许疏散时间的计算 . 43 4.2 房间疏散时间 . 44