1、 西安机修厂金工车间设计 摘 要 本工程为单层双跨等高钢筋混凝土排架结构,跨度为 18 米,柱距为 6.0 米,厂房总长度为 60 米,每跨设有两台 200/50kN 吊车。本设计内容有建筑设计:平面、立面、剖面等设计;结构设计:确定单层厂房的结构方案,进行了结构内力分析,包括排架计算简图的确定,作用在排架上各种荷载的计算;最不利内力组合等,在此基础上对柱,牛腿和基础进行了配配筋设计算并绘制了施工图。 关键字 :单层工业厂房 ;排架结构 ;柱 ; 基础 Xian repair words shop metal working workshop abstract The project is a
2、 one-floor and two-span reinforceed concrete bent structure.All the spans are 24 meters,the distance between the columns are 6.0 meters,and the total length is 72 meters. Every span bears two cable cars of 200/50kN. First, we should design the structure of the single story workshop, then we should a
3、nalyze its internal force including the determination of bent calculation diagram, the calculation of the loads subjected to the bent, the analysis of the internal forces of the structure and the most unfavorable combination of the columns cross sections, and so on. At last , based on the work done
4、above, the columns reinforcement , corbel and the foundation were determined and the reinforcement drawing was done. Key Words:single industral plants;Bent structure;column;base; 目 录 设计资料 1 第一章建筑设计 立面设计 3 平面设计 3 剖面设计 4 局部构造设计 5 第二章结构设计 2.1 柱截面尺寸确定 6 2.2 荷载计算 7 2.2.1 恒载 7 2.2.2 屋面活荷载 8 2.2.3 风荷载 8 2.
5、2.4 吊车 荷载 9 2.3 排架内力分析 10 2.3.1、恒载作用下排架的内力分析 11 2.3.2、屋面活荷载作用下排架内力分析 12 2.3.3、风荷载作用下排架内力分析 14 2.3.4、吊车荷载作用下排架内力分析 16 2.4 内力组合 21 2.5 柱截面设计 24 2.5.1、上柱配筋计算 24 2.5.2、下柱配筋计算 25 2.5.3、柱的裂缝宽度验算 26 2.5.4、柱箍筋配置 27 2.5.5、牛腿设计 28 2.5.6、柱的吊装验算 29 2.6 基础设计 31 2.6.1、作用于基础顶面上的荷载计算 31 2.6.2、基础尺寸及埋置深度 32 2.6.3、基础高度验算 33 2.6.4、基础底板配筋计算 37 参考文献 38 致谢 39