1、 南京工程学院毕业设计 外 文 资 料 翻 译 学 生 姓 名: 钱亚宾 学 号: 240084415 班 级 名 称: K 建工 082 所 在 院 系: 建筑工程学院 Talling building and Steel construction Although there have been many advancements in building construction technology in general. Spectacular archievements have been made in the design and construction of ultrahig
2、h-rise buildings. The early development of high-rise buildings began with structural steel framing.Reinforced concrete and stressed-skin tube systems have since been economically and competitively used in a number of structures for both residential and commercial purposes.The high-rise buildings ran
3、ging from 50 to 110 stories that are being built all over the United States are the result of innovations and development of new structual systems. Greater height entails increased column and beam sizes to make buildings more rigid so that under wind load they will not sway beyond an acceptable limi
4、t.Excessive lateral sway may cause serious recurring damage to partitions,ceilings.and other architectural details. In addition,excessive sway may cause discomfort to the occupants of the building because their perception of such motion.Structural systems of reinforced concrete,as well as steel,take
5、 full advantage of inherent potential stiffness of the total building and therefore require additional stiffening to limit the sway. In a steel structure,for example,the economy can be defined in terms of the total average quantity of steel per square foot of floor area of the building.Curve A in Fi
6、g .1 represents the average unit weight of a conventional frame with increasing numbers of stories. Curve B represents the average steel weight if the frame is protected from all lateral loads. The gap between the upper boundary and the lower boundary represents the premium for height for the tradit
7、ional column-and-beam frame.Structural engineers have developed structural systems with a view to eliminating this premium. Systems in steel. Tall buildings in steel developed as a result of several types of structural innovations. The innovations have been applied to the construction of both office
8、 and apartment buildings. Frame with rigid belt trusses. In order to tie the exterior columns of a frame structure to the interior vertical trusses,a system of rigid belt trusses at mid-height and at the top of the building may be used. A good example of this system is the First Wisconsin Bank Build
9、ing(1974) in Milwaukee. Framed tube. The maximum efficiency of the total structure of a tall building, for both strength and stiffness,to resist wind load can be achieved only if all column element can be connected to each other in such a way that the entire building acts as a hollow tube or rigid b
10、ox in projecting out of the ground. This particular structural system was probably used for the first time in the 43-story reinforced concrete DeWitt Chestnut Apartment Building in Chicago. The most significant use of this system is in the twin structural steel towers of the 110-story World Trade Ce
11、nter building in New York Column-diagonal truss tube. The exterior columns of a building can be spaced reasonably far apart and yet be made to work together as a tube by connecting them with diagonal members interesting at the centre line of the columns and beams. This simple yet extremely efficient
12、 system was used for the first time on the John Hancock Centre in Chicago, using as much steel as is normally needed for a traditional 40-story building. Bundled tube. With the continuing need for larger and taller buildings, the framed tube or the column-diagonal truss tube may be used in a bundled
13、 form to create larger tube envelopes while maintaining high efficiency. The 110-story Sears Roebuck Headquarters Building in Chicago has nine tube, bundled at the base of the building in three rows. Some of these individual tubes terminate at different heights of the building, demonstrating the unl
14、imited architectural possibilities of this latest structural concept. The Sears tower, at a height of 1450 ft(442m), is the worlds tallest building. Stressed-skin tube system. The tube structural system was developed for improving the resistance to lateral forces (wind and earthquake) and the contro
15、l of drift (lateral building movement ) in high-rise building. The stressed-skin tube takes the tube system a step further. The development of the stressed-skin tube utilizes the fa?ade of the building as a structural element which acts with the framed tube, thus providing an efficient way of resist
16、ing lateral loads in high-rise buildings, and resulting in cost-effective column-free interior space with a high ratio of net to gross floor area. Because of the contribution of the stressed-skin fa?ade, the framed members of the tube require less mass, and are thus lighter and less expensive. All the typical columns and spandrel beams are standard rolled shapes,minimizing the use and cost of special built-up members. The depth