1、 2.4GHz T-bus EIB smart hospital control system Modernized hospital construction function is complicated, medical equipment is precise, the environment request standard is high, using 2.4GHz T-bus intelligence control system can connect to the hospital construction environment. Through the establish
2、ment of digitization energy conservation medical service environment, may enhance the hospital management level, enhances medical personnels working efficiency, save the hospital operation costs. T-bus intelligence environment control system realize the optimizing control to the light environment, t
3、he visor environment, the temperature environment and the medical equipment movement and maintenance of many hospital departments such as outpatient clinic, the in-patient department and so on through controlling to each kind of terminal electrical equipment (for example light, electrical window cur
4、tain, air conditioners, medical equipment and so on). Purposes: 1. Uniformly Manages, controls and protects the hospital illumination, air conditioners and the medical equipment 2. Enhances the hospital service scale, provides the comfortable environment to the medical person and the patients. 3. Sa
5、ve the energy, saves the hospital operation costs 4. uses the safe voltage the weak electricity board to substitute the strong electricity board, enhanced the security; Through the electric current and the leakage electric current examination to the important medical equipment, promptly reported in
6、the breakdown situation, strengthened the medical equipment reliability and security. Functions: 1. Light control of ward and outpatient service building 2. Electrical window curtain and visor volume curtain control of ward and outpatient service building 3. Air conditioner, heats up and the air blo
7、wer plate tube control of ward and outpatient service building 4. Illumination and the light adjusting of the operating room and the treatment room 5. Hospital ward ringing system 6. AV device control of academic exchange center and conference room 7. Illumination electrical power distribution syste
8、m and fire linkage 8. Linkage hospital automation office system, to realize to have no paper work 9. All T-bus system intelligent controllers circuit breaker of Outpatient service and in-patient department and important medical equipment circuit breaker condition surveillance 10. Centralism monitor
9、and control of the outpatient service and the hospital ward to achieve the non- board control in the public region Controlled area and control content: 1. hospital ward Control of light, electric curtain, fan coil unit, ringing system, the socket of microwave oven and so on , ultraviolet ray sterili
10、zation lamp 2. Outpatient service hall Control of light, visor volume curtain, fan coil unit 3. The departments of the treatment, the inspection, the surgery, the diagnosis, rescue and so on. Control of light, electric curtain, fan coil unit 4. Common aisle, elevator hall Control of light, undergrou
11、nd lamp control 5. Academic exchange center, report hall Control of light, AV equipment, window electric curtain, theater curtain; 6. Extensive lighting, botanical garden illumination Control of light 7. Center control computer Solutions: 1. Hospital ward * Installs 8 path 2.4GHz T-bus system intell
12、igent controllers beside the bed, controls the light switch and adjusts the light in the guest room, controls the opening and closing of the electric curtain, may carry on the master switch control to the hospital ward light, may control the bathroom light, and may set the doctors clinic scene, the
13、rest scene, the television watching scene. * The angle of the hospital ward electrically operated bed can be adjusted through the T-bus system intelligent controllers and the remote control, facilitates the doctors clinic and the patient dines, reads; * Guardianship ringing system. When the patient
14、needs the guardianship the patients feeling is not good, may press the call button or the remote control nearby the bed, the on-duty nurse may rush to the hospital ward to carry on processing immediately; * The center control computer in Each floor nurse stand can implement the common control to var
15、ious illumination, the curtain and the air-conditioner system at hospital wards in corresponding floor, and the computer of each nurse stand can demonstrate the indoor temperature in each hospital ward, simultaneously may establish the maximum and minimum temperature, provides the human nature servi
16、ce; * The hospital ward corridor illumination may automatically open by coordinating with the light sensor and the timers, when the degree of illumination request is very low at the deeper night, shuts down partial illuminations light, the foot light automatically opens. * The nurse station may real
17、ize centralism monitoring to the sockets of various medical equipments such as breath machine and so on in the ward. * Installs a intelligent switch with a temperature control board at the entrance, carries on the automatic constant temperature control to the fan coil unit of the hospital ward, may
18、demonstrate the indoor temperature, simultaneously may carry on the control to the light and the curtain. * Installs intelligence switch at the bathroom entrance, may carry on the control to the bathroom light and the ventilating fan * If with intelligent door lock system linkage, may realize the di
19、fferent opening gate pattern between the doctor and the service person, named the clinic pattern and the sweeps clear pattern. * After the patient Check-in, automatically adjusts the light and the electric curtain at the corresponding ward to in-patient pattern, adjusts the air conditioner temperatu
20、re to comfortable temperature. Enables the patient to have the home feeling and enhances the hospital service scale. * After the patient left, automatically adjusts the light and the electric curtain at the corresponding ward to closure pattern, may automatically restore the ward hypothesis temperat
21、ure to the condition which tacitly approves. * After the patient goes to sleep at night, T-bus temperature controls board automatically changes to energy conservation pattern. According to the statistics, the hypothesis temperature elevates 1 (when refrigeration) or reduces 1 (when heats up) every t
22、ime, may conserve energy 6% * The center control room may demonstrate the actual temperature and the hypothesis temperature of each hospital ward. Also may set the maximum and minimum temperature. Simultaneously the hospital ward temperature control also may connect with the window linkage, after th
23、e window is turned on, automatically closes the air conditioner to realize energy conservation fully. * T-bus temperature controls board can automatically control Fan coil unit. When the indoor temperature approaches the hypothesis temperature, automatically adjusts wind speed from high to low, make
24、s the indoor temperature to maintain around the hypothesis temperature, to save energy and it is very comfortable. * When summer sunlight is intense, automatically shut-off ward curtain, prevented the ward temperature to be excessively high, achieves the energy conservation purpose. 2. Outpatient se
25、rvice hall * Automatically control degree of illumination of the outpatient hall through lit sensor at day time. When the natural light is intense, closes partial lights, otherwise, then opens the certain light, makes the outpatient hall to maintain the constant degree of illumination. Simultaneousl
26、y may conserve energy. * At night may act different degree of illumination according to the patient current capacity. * Controls the visor volume curtain of the hall through the light sensor. When the summer light is intense, automatically lays down the visor volume curtain, in order to conserves energy.